generate by the inverter, those appliances may not work or may be damaged if they are
connected to the inverter. If you are unsure about powering any device with the inverter, contact
the manufacturer of the device.
Estimate Run time on Load
Following run time is an estimate based on using a 12V-120AH battery bank for reference. Actual
run time may vary.
Load Consumption Estimate Run time
Cordless Phone 5W 180 hrs
Clock/Radio 8W 135 hrs
Table Lamp 40W/60W 27 hrs/ 18 hrs
Freezer (8.8 cu. ft.) 80W 15 hrs
20” LCD TV 100W 11.5 hrs
Refrigerator (18 cu. ft.) 120W 9 hrs
Sump Pump (1/2 hp) 350W 3 hrs
Microwave (mid-size) 1000W 49 min
Coffee Maker 1200W 37 min
5. TROUBLESHOOTING
To trouble shoot the unit, please note the error code display on the main unit and review the
“Understanding the Error Codes” in section 4.
Problem Symptom Solution
No output voltage.
And Status LED is
off.
The unit is off Turn unit ON by following the instruction in
Section 4 to turn unit ON
No power to inverter Check fuse or the Disconnect switch (if
installed) is either blown or turn OFF
No AC output.
Status LED is
Green
GFCI was tripped Check load and reset the GFCI
No Output. Status
LED is in Amber
Check error code on
display
Verify the error condition and make
correction
Products
connected to unit
malfunction or
overheat
Products connected to
unit do not accept
modified sine wave output
(MW1210 & MW1215
only)
Products are not compatible with the
modified sine wave output generated by the
KISAE Power Inverter. See “AC Load on
Power Inverter” in Section 4